Konstantin Dotchkoff created MQTT-464:
-----------------------------------------

             Summary: Add reason code 150 to PUBACK packet
                 Key: MQTT-464
                 URL: https://issues.oasis-open.org/browse/MQTT-464
             Project: OASIS Message Queuing Telemetry Transport (MQTT) TC
          Issue Type: Improvement
    Affects Versions: wd14
            Reporter: Konstantin Dotchkoff
             Fix For: wd14


Line 2111: Table 3-5 - PUBACK Reason Codes
need to add code value 150 (0x96) "Message rate too high" to the table.

Line 881: Table 2-4 Reason Codes
add PUBACK in the Packets column for Value 150 (0x96) "Message rate too high" 

This code is different than return code 151 and needed for PUBACK, to inform the Sender that it has temporarily exceeded the throughput limit (vs. the cumulative (daily/monthly) quota for a customer, represented by value 151).



--