Hi Bob,
I missed the first part of that discussion. Was that an question
that came in through the mailing lists? Or a question that came
to you directly through RedHad?
It came directly I've been meaning to post the question to the
mailing list and never got to it.
I had to go back through some old emails... but there is the
BSI-TR-0311 standard which does define ECDH where both X and Y
coordinates are returned from the ECDH primitive, and where it
does appear to use the X and Y coordinates as input to the KDF.
We (Safenet) were asked about our compliance with TR-0311, and I
pointed out that our products only return X, but I never got any
more response from them on this topic.
Not sure if this is of any interest to you or not.
Hmm it is. I was thinking of which way to go post 3.0 to get what we
need:
1) a new KDF that returns X and Y.
2) a new mechanism that returns X and Y.
3) full set of mechanisms needed to support McCallum/Relyea.
This input leads me to to think 1 and 2 would be viable options.