← Prev in month
← Prev in thread
[NEW ISSUE]: Section on "Wire" in Appendix is Incorrect
Raiser: Mike Edwards Target document: SCA Assembly Specification, CD01-Rev1 Description: Lines 4406 / 4407 say: "Within a composite, valid wire sources are component references and composite services. Valid wire targets are component services and composite references." This is incorrect. Wires cannot connect to composite services or composite references. Proposal: Replace lines 4406 / 4407 with the following text: "Valid wire sources are component references. Valid wire targets are component services". Yours, Mike. Strategist - Emerging Technologies, SCA & SDO. Co Chair OASIS SCA Assembly TC. IBM Hursley Park, Mail Point 146, Winchester, SO21 2JN, Great Britain. Phone & FAX: +44-1962-818014 Mobile: +44-7802-467431 Email: Unless stated otherwise above: IBM United Kingdom Limited - Registered in England and Wales with number 741598. Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6 3AU