← Prev in month
← Prev in thread
Next in thread →
Next in month →
ISSUE 56: Need to clarify definition of Bidirectional Interfaces -Proposal text
Folks, Here is the proposal text for Issue 56 ----------------------------------------------------------------------------------------- Preamble. In the Issue text, Tom Rutt posed 3 questions, which are not answered by the current specification, each of which needs an answer - following that is formal specification text which is proposed to be added to the specification. 1) Does every operation type invoked onto the "service interface" direction have the potential to have correlated callback interface operations in the opposite direction? Answer: In principle, any one of the forward interface operations may cause zero, one or many invocations on the callback interface by the service provider. For each of the forward service operations, any of the operations on the callback interface may get invoked, in any order. This is a case of "maximum flexibility, minimum information". The service provider gets to use the callback interface in any way that makes sense - but it gives the client a hard time in working out what will happen for a given invocation. For the client to get more information, extra metadata is required which is not captured by SCA today. 2) Does every operation invocation invoked onto the callback interface have to be considered as a callback for an operation invocation on the service interface? Answer: Every invocation on an operation of the callback interface is considered to be the result of some operation invoked on the forward service interface. 3) How can it be specified (at design time) which operation types defined in the callback interface description can be correlated with which individual operation types defined in the service interface description? Answer: This kind of metadata about the service and the callback must be provided outside the standard SCA metadata. It could be done through informal documentation. It could be done by more formal means (one possibility might be to use abstract BPEL to indicate the sequencing of messages). SCA leaves this open to the creator of the callback interface and the service that uses it. The problem in the general case is to convey alternatives. In the simplest case, one forward call results in exactly one invocation of the callback interface (see Isseue 33 and the "long running request/response" pattern as an example of this). However, there are plenty of existing examples of asynchronous sequences much more complex than this. Even ordering a book with Amazon has this potential for complex interactions - one request to order a set of books results (usually) in at least 2 responses - one accepting the order and one indicating dispatch of the package. However, not all the order may get dispatched at once and a sequence of messages for each dispatch can occur. It is also possible that one or more books is not available for some lenghy period, in which case a callback message is sent which gives the client the opportunity to cancel that part of the order. OK, this is all done with email, but it is possible to see that similar sequences could apply to order processing offered as Web services. ----------------------------------------------------------------------------------------- Proposed text for the Assembly specification (CD-01), to be added after line 2333 In a bidirectional interface, the service interface can have more than one operation defined, and the callback interface can also have more than one operation defined. A single invocation of an operation on the service interface can cause zero, one or many invocations of any of the operations on the callback interface. For a given invocation of a service operation, which operations are invoked on the callback interface, the number of operations invoked and their sequence are not described by SCA. It is possible that this metadata about the bidirectional interface can be supplied through mechanisms outside SCA. For example, it might be provided as a written description attached to the callback interface. ----------------------------------------------------------------------------------------- Yours, Mike. Strategist - Emerging Technologies, SCA & SDO. Co Chair OASIS SCA Assembly TC. IBM Hursley Park, Mail Point 146, Winchester, SO21 2JN, Great Britain. Phone & FAX: +44-1962-818014 Mobile: +44-7802-467431 Email: Unless stated otherwise above: IBM United Kingdom Limited - Registered in England and Wales with number 741598. Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6 3AU
← Prev in month
← Prev in thread
Next in thread →
Next in month →