NEW ISSUE: Clarify default data binding for JMS when sending messages

From
Simon Holdsworth <>
Date
2008-10-06T14:24:50+00:00
ID
Thread
NEW ISSUE: Clarify default data binding for JMS when sending messages
TARGET: SCA JMS Binding Specification
CD-01

DESCRIPTION: 

The JMS default data binding is written
mostly in terms of how to handle JMS messages that are received.  It
does not explicitly address how JMS messages are created when they are
sent.  It also does not include the setting of the scaOperationName
user property to be consistent with the default operation selection algorithm

PROPOSAL:

Update:

Otherwise, the JMSMessage must be a JMS text
message or bytes message containing XML;
an SCA runtime MUST be able to receive both forms. When sending messages
either form may be used; an SCA runtime MAY provide additional configuration
to allow one or other to be selected.

Add:

When sending messages, if there is a
single parameter, the JMS user property "scaOperationName" MUST
be set to the name of the operation being invoked.

Regards, Simon