Folks,

When applying the resolution to issue
BINDINGS-47 I discovered that we already talk about setting the "scaOperationName"
in the operation selection section.  Given that operation selection
is not about creating messages, I think that the following sentence should
be removed from the operation selection section:

When sending a request from a reference, or
a callback from a service, if the interface includes more than one operation
then the “scaOperationName” JMS user property is set to
the name of the operation being invoked.

Also, this text indicates that the scaOperationName
property is only set when there is more than one operation in the interface.
 To preserve this behaviour, the updated text in the data binding
section should read:

When sending request messages, if there is
a single parameter and the interface includes more than one operation,
the SCA runtime MUST set the JMS user property "scaOperationName"
to the name of the operation being invoked.

I intend to make this an editorial change
unless anyone objects in which case we'll need to handle this with a new
issue.

Regards, Simon

Simon Holdsworth

STSM, SCA Bindings Architect; Master Inventor; OASIS SCA Bindings TC Chair

MP 211, IBM UK Labs, Hursley Park, Winchester SO21 2JN, UK

Tel +44-1962-815059 (Internal 245059) Fax +44-1962-816898

Internet - 

Unless stated otherwise above:

IBM United Kingdom Limited - Registered in England and Wales with number
741598. 

Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6
3AU
← Prev in month ← Prev in thread