NEW ISSUE: JMS Default wire format insufficient to cover real world usage

From
Simon Holdsworth <>
Date
2008-12-19T12:06:14+00:00
ID
Thread
NEW ISSUE: JMS Default wire format insufficient to cover real world usage
TARGET: SCA JMS Binding Specification
cd01

DESCRIPTION: 

The default wire format and operation
selector defined in the JMS binding spec are provided as minimum functionality,
primarily to ensure that messages sent by a reference with a JMS binding
can be received and correctly processed by a service with a JMS binding
without any additional vendor-specific configuration.

However these elements require a specific
wire representation, where in general JMS applications will tend to use
a variety of other wire formats requiring different operation selectors.
 Without any additional wireFormat and operationSelector elements
defined as standard, integration with these applications will require vendor-specific
extensions which will limit portability.

PROPOSAL:

We need to consider whether there are
any additional wireFormats or operationSelectors we should include in the
JMS binding spec (or assembly spec if applicable).

Some possible examples (half-baked,
not intended to be a formal proposal, just to provoke discussion):

wireFormat.xml   -  has the
behaviour defined for the default binding, specifically when the message
is the XML serialization of the interface (not JMS-specific)

wireFormat.jmsMessage  - when the
interface has JMS message as the parameter

wireFormat.bytes  -  when
there is a single byte[] parameter (not JMS-specific)

wireFormat.text   - when there
is a single string parameter (not JMS-specific)

wireFormat.fixedWidth  - message
consists of values of fixed widths with a defined mapping to the parameters
in the interface (not JMS-specific)

wireFormat.separated  - message
consists of values with a given separator with a defined mapping to the
parameters in the interface (not JMS-specific)

wireFormat.dfdl   -  message
structure is defined via WSDL annotations as described by Data Format Description
Language (not JMS-specific)

wireFormat.xslt   -  message
structure is defined via XSLT (not JMS-specific)

operationSelector.jmsUser  -  selected
operation name is passed in the specified JMS user property

operationSelector.jmsType  -  selected
operation name is the type of the JMS message

operationSelector.fixed    
  -  selected operation name is the specified value (not JMS-specific)

operationSelector.singleOperation  -
 when the interface has a single operation (not JMS-specific)

Simon Holdsworth

STSM, SCA Bindings Architect; Master Inventor; OASIS SCA Bindings TC Chair

MP 211, IBM UK Labs, Hursley Park, Winchester SO21 2JN, UK

Tel +44-1962-815059 (Internal 245059) Fax +44-1962-816898

Internet - 

Unless stated otherwise above:

IBM United Kingdom Limited - Registered in England and Wales with number
741598. 

Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6
3AU
← Prev in month ← Prev in thread
Next in thread → Next in month →