NEW ISSUE: No defined behaviour in JMS binding if resolved operation namenot present in interface
TARGET: SCA JMS Binding Specification CD-03 DESCRIPTION: The JMS binding defines the operation resolution mechanism, however it does not say what happens when the resolved operation name does not match any of the operations in the interface. We need to state that this is an error via a normative statement. As an aside, the behaviour described with respect to operation selector, resolved operation name and target component is actually generic and so we ought to consider whether it actually belongs in the assembly spec (possibly along with the operationProperties element...) PROPOSAL: Modify BJM40010 as follows: When a message is received at an SCA service with JMS binding, the SCA runtime MUST invoke the target component using the resolved operation name if that name is present in the target component's interface, otherwise the SCA runtime MUST raise an error [BJM40010]. Regards, Simon Simon Holdsworth STSM, SCA Bindings Architect; Master Inventor; OASIS SCA Bindings TC Chair MP 211, IBM UK Labs, Hursley Park, Winchester SO21 2JN, UK Tel +44-1962-815059 (Internal 245059) Fax +44-1962-816898 Internet - Unless stated otherwise above: IBM United Kingdom Limited - Registered in England and Wales with number 741598. Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6 3AU