← Prev in month ← Prev in thread
Next in thread → Next in month →

NEW ISSUE: No defined behaviour in JMS binding if resolved operation namenot present in interface

From
Simon Holdsworth <>
Date
2009-11-05T13:49:22+00:00
ID
Thread
NEW ISSUE: No defined behaviour in JMS binding if resolved operation namenot present in interface
TARGET: SCA JMS Binding Specification
CD-03

DESCRIPTION: 

The JMS binding defines the operation
resolution mechanism, however it does not say what happens when the resolved
operation name does not match any of the operations in the interface.  We
need to state that this is an error via a normative statement.

As an aside, the behaviour described
with respect to operation selector, resolved operation name and target
component is actually generic and so we ought to consider whether it actually
belongs in the assembly spec (possibly along with the operationProperties
element...)

PROPOSAL:

Modify BJM40010 as follows:

When a message is received at an SCA
service with JMS binding, the SCA runtime MUST invoke the target component
using the resolved operation name if that name is present in the target
component's interface, otherwise the SCA runtime MUST raise an error [BJM40010].

Regards, Simon

Simon Holdsworth

STSM, SCA Bindings Architect; Master Inventor; OASIS SCA Bindings TC Chair

MP 211, IBM UK Labs, Hursley Park, Winchester SO21 2JN, UK

Tel +44-1962-815059 (Internal 245059) Fax +44-1962-816898

Internet - 

Unless stated otherwise above:

IBM United Kingdom Limited - Registered in England and Wales with number
741598. 

Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6
3AU
← Prev in month ← Prev in thread
Next in thread → Next in month →